Accuracy, Preference, Comfort, and Chairside Time Using Digital Intraoral Scanner in Children: A Scoping review
DOI:
10.29303/jppipa.v11i8.11269Published:
2025-08-25Downloads
Abstract
This study aims to evaluate the accuracy, preference, comfort, and impression-taking time of digital intraoral scanners in children. Literature was sourced from Scopus, ScienceDirect, Wiley, and PubMed (2014–2024). From 124 identified articles, 22 were duplicates, and 11 met the inclusion criteria and were assessed using the CEBM Appraisal Tools. These 11 articles were included in the final analysis. Data were organized following the PRISMA Extension for Scoping Reviews guidelines. Results of the 11 studies, 3 concluded that digital intraoral scanners are more accurate than conventional methods, 3 found equivalent accuracy, and 5 did not evaluate accuracy. Five articles showed children preferred the digital intraoral scanner over conventional methods, while 6 did not address preference. Regarding comfort, 5 articles reported that children felt more comfortable using the digital scanner, 1 article reported equal comfort, and 5 did not evaluate comfort. For impression-taking time, 1 article reported faster scanning times, 2 reported longer times, 2 found similar durations, and 6 did not discuss impression time. Conclusion: Scientific evidence regarding the use of digital intraoral scanners in children remains limited. While their accuracy is generally comparable to conventional methods, children tend to show better preference and comfort. However, findings related to impression-taking time vary, indicating a need for further research using standardized instruments to draw definitive conclusions.
Keywords:
Dental Impression Procedure Digital Intraoral Scanners Pediatric DentistryReferences
Alzahrani, S. J., EL-Hammali, H., Morgano, S. M., & Elkassaby, H. (2021). Evaluation of the accuracy of 2 digital intraoral scanners: A 3D analysis study. Journal of Prosthetic Dentistry, 126(6). https://doi.org/10.1016/j.prosdent.2020.10.004
Anh, J. W., Park, J. M., Chun, Y. S., Kim, M., & Kim, M. (2016). A comparison of the precision of three-dimensional images acquired by 2 digital intraoral scanners: Effects of tooth irregularity and scanning direction. Korean Journal of Orthodontics, 46(1). https://doi.org/10.4041/kjod.2016.46.1.3
Asar, N. V., Yun, S., Schwartz, S., & Turkyilmaz, I. (2022). Analysis of the relationship between the surface topography of prepared tooth surfaces and data quality of digital impressions from an intraoral scanner. Journal of Dental Sciences, 17(1). https://doi.org/10.1016/j.jds.2021.07.013
Bosoni, C., Nieri, M., Franceschi, D., Souki, B. Q., Franchi, L., & Giuntini, V. (2023). Comparison between digital and conventional impression techniques in children on preference, time and comfort: A crossover randomized controlled trial. Orthodontics and Craniofacial Research, 26(4), 585–590. https://doi.org/10.1111/ocr.12648
Burhardt, L., Livas, C., Kerdijk, W., van der Meer, W. J., & Ren, Y. (2016). Treatment comfort, time perception, and preference for conventional and digital impression techniques: A comparative study in young patients. American Journal of Orthodontics and Dentofacial Orthopedics, 150(2), 261–267. https://doi.org/10.1016/j.ajodo.2015.12.027
Burzynski, J. A., Firestone, A. R., Beck, F. M., Fields, H. W., & Deguchi, T. (2018). Comparison of digital intraoral scanners and alginate impressions: Time and patient satisfaction. American Journal of Orthodontics and Dentofacial Orthopedics, 153(4). https://doi.org/10.1016/j.ajodo.2017.08.017
Chiu, A., Chen, Y. W., Hayashi, J., & Sadr, A. (2020). Accuracy of CAD/CAM digital impressions with different intraoral scanner parameters. Sensors (Switzerland), 20(4). https://doi.org/10.3390/s20041157
Christopoulou, I., Kaklamanos, E. G., Makrygiannakis, M. A., Bitsanis, I., Perlea, P., & Tsolakis, A. I. (2022). Intraoral Scanners in Orthodontics: A Critical Review. International Journal of Environmental Research and Public Health, 19(3). https://doi.org/10.3390/ijerph19031407
Giachetti, L., Sarti, C., Cinelli, F., & Russo, D. (2020). Accuracy of Digital Impressions in Fixed Prosthodontics: A Systematic Review of Clinical Studies. The International Journal of Prosthodontics, 33(2). https://doi.org/10.11607/ijp.6468
Glisic, O., Hoejbjerre, L., & Sonnesen, L. (2019). A comparison of patient experience, chair-side time, accuracy of dental arch measurements and costs of acquisition of dental models. Angle Orthodontist, 89(6), 868–875. https://doi.org/10.2319/020619-84.1
Gökmen, Ş., Topsakal, K. G., Duran, G. S., & Görgülü, S. (2024). Clinical comparative study on the accuracy of palatal rugae in models obtained by different impression materials and intraoral scanning. Clinical Oral Investigations, 28(2). https://doi.org/10.1007/s00784-024-05556-y
Goracci, C., Franchi, L., Vichi, A., & Ferrari, M. (2016). Accuracy, reliability, and efficiency of intraoral scanners for full-arch impressions: A systematic review of the clinical evidence. European Journal of Orthodontics, 38(4). https://doi.org/10.1093/ejo/cjv077
Hayama, H., Fueki, K., Wadachi, J., & Wakabayashi, N. (2018). Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible. Journal of Prosthodontic Research, 62(3). https://doi.org/10.1016/j.jpor.2018.01.003
Khatuja, N. G., Katiyar, P., Tarannum, F., Pandey, K. K., Katiyar, A. K., Afzal, Z., Ali, A., & Roy, I. (2023). Comparative Analysis of Three Different Impression Techniques for Impression Defects and Dimensional Accuracy Using a Digital Intraoral Scanner for Fixed Partial Dentures: An In Vivo Study. Cureus. https://doi.org/10.7759/cureus.38461
Kumar, S., Keeling, A., Osnes, C., Bartlett, D., & O’Toole, S. (2019). The sensitivity of digital intraoral scanners at measuring early erosive wear. Journal of Dentistry, 81. https://doi.org/10.1016/j.jdent.2018.12.005
Lee, K. C., & Park, S. J. (2020). Digital intraoral scanners and alginate impressions in reproducing full dental arches: A comparative 3D assessment. Applied Sciences (Switzerland), 10(21). https://doi.org/10.3390/app10217637
Lee, S. J., Kim, S. W., Lee, J. J., & Cheong, C. W. (2020). Comparison of intraoral and extraoral digital scanners: Evaluation of surface topography and precision. Dentistry Journal, 8(2). https://doi.org/10.3390/dj8020052
Liczmanski, K., Stamm, T., Sauerland, C., & Blanck-Lubarsch, M. (2020). Accuracy of intraoral scans in the mixed dentition: A prospective non-randomized comparative clinical trial. Head and Face Medicine, 16(1). https://doi.org/10.1186/s13005-020-00222-6
Lim, J. H., Park, J. M., Kim, M., Heo, S. J., & Myung, J. Y. (2018). Comparison of digital intraoral scanner reproducibility and image trueness considering repetitive experience. Journal of Prosthetic Dentistry, 119(2). https://doi.org/10.1016/j.prosdent.2017.05.002
Lipani, E., Garcovich, D., Martin, M. A., Dioguardi, M., Re, D., & Aiuto, R. (2024). Digital dentistry in the clinical practice of the pediatric dentist: a scoping review. Dental Cadmos, 92(8), 650–661. https://doi.org/10.19256/d.cadmos.08.2024.05
Mack, S., Bonilla, T., English, J. D., Cozad, B., & Akyalcin, S. (2017). Accuracy of 3-dimensional curvilinear measurements on digital models with intraoral scanners. American Journal of Orthodontics and Dentofacial Orthopedics, 152(3). https://doi.org/10.1016/j.ajodo.2017.05.011
Mangano, A., Beretta, M., Luongo, G., Mangano, C., & Mangano, F. (2018). Conventional Vs Digital Impressions: Acceptability, Treatment Comfort and Stress Among Young Orthodontic Patients. The Open Dentistry Journal, 12(1), 118–124. https://doi.org/10.2174/1874210601812010118
Motel, C., Kirchner, E., Adler, W., Wichmann, M., & Matta, R. E. (2020). Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study. Journal of Prosthodontics, 29(4). https://doi.org/10.1111/jopr.13131
Pahuja, N., Doneria, D., & Mathur, S. (2023). Comparative Evaluation of Accuracy of Intraoral Scanners vs Conventional Method in Establishing Dental Measurements in Mixed Dentition. World Journal of Dentistry, 14(5), 419–424. https://doi.org/10.5005/jp-journals-10015-2231
Parizotto, R. A., Cavalli, V., Zandoná, R. L., de Carvalho, G. A. P., Franco, A. B. G., Ramos, E. V., & Dias, S. C. (2023). Use of scanning electron microscope to evaluate the marginal fit of protocol bars obtained through benchtop or intraoral digital scanners. Brazilian Journal of Oral Sciences, 22. https://doi.org/10.20396/bjos.v22i00.8669079
Park, H. R., Park, J. M., Chun, Y. S., Lee, K. N., & Kim, M. (2015). Changes in views on digital intraoral scanners among dental hygienists after training in digital impression taking. BMC Oral Health, 15(1). https://doi.org/10.1186/s12903-015-0140-5
Róth, I., Czigola, A., Fehér, D., Vitai, V., Joós-Kovács, G. L., Hermann, P., Borbély, J., & Vecsei, B. (2022). Digital intraoral scanner devices: a validation study based on common evaluation criteria. BMC Oral Health, 22(1). https://doi.org/10.1186/s12903-022-02176-4
Rutkūnas, V., Dirsė, J., & Bilius, V. (2020). Accuracy of an intraoral digital scanner in tooth color determination. Journal of Prosthetic Dentistry, 123(2). https://doi.org/10.1016/j.prosdent.2018.12.020
Rutkūnas, V., Gečiauskaitė, A., Jegelevičius, D., & Vaitiekūnas, M. (2017). Accuracy of digital implant impressions with intraoral scanners. A systematic review. European Journal of Oral Implantology, 10(Suppl 1), 101-120. Retrieved from https://shorturl.at/r7YG8
Sanda, M., Miyoshi, K., & Baba, K. (2021). Trueness and precision of digital implant impressions by intraoral scanners: a literature review. International Journal of Implant Dentistry, 7(1). https://doi.org/10.1186/s40729-021-00352-9
Schieffer, L., Latzko, L., Ulmer, H., Schenz-Spisic, N., Lepperdinger, U., Paulus, M., & Crismani, A. G. (2022). Comparison between stone and digital cast measurements in mixed dentition: Validity, reliability, reproducibility, and objectivity. Journal of Orofacial Orthopedics, 83, 75–84. https://doi.org/10.1007/s00056-022-00376-9
Serrano-Velasco, D., Martín-Vacas, A., Cintora-López, P., Paz-Cortés, M. M., & Aragoneses, J. M. (2024). Comparative Analysis of the Comfort of Children and Adolescents in Digital and Conventional Full-Arch Impression Methods: A Crossover Randomized Trial. Children, 11(2). https://doi.org/10.3390/children11020190
Serrano-Velasco, D., Martín-Vacas, A., Giovannini, G., Paz-Cortés, M. M., & Aragoneses, J. M. (2024). Accuracy Analysis of Digital Models from Intraoral Scanners and 3D-Printed Casts in Children and Teenagers. Children, 11(9), 1082. https://doi.org/10.3390/children11091082
Su, T. S., & Sun, J. (2015). Comparison of repeatability between intraoral digital scanner and extraoral digital scanner: An in-vitro study. Journal of Prosthodontic Research, 59(4). https://doi.org/10.1016/j.jpor.2015.06.002
Suese, K. (2020). Progress in digital dentistry: The practical use of intraoral scanners. Dental Materials Journal, 39(1), 52–56. https://doi.org/10.4012/dmj.2019-224
Sugiyono. (2022). Metode penelitian kuantitatif, kualitatif, dan R&D. Alfabeta.
Takeuchi, Y., Koizumi, H., Furuchi, M., Sato, Y., Ohkubo, C., & Matsumura, H. (2018). Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses. In Journal of Oral Science, 60(1). https://doi.org/10.2334/josnusd.17-0444
Yilmaz, H., & Aydin, M. N. (2019). Digital versus conventional impression method in children: Comfort, preference and time. International Journal of Paediatric Dentistry, 29(6), 728–735. https://doi.org/10.1111/ipd.12566
Zarbakhsh, A., Jalalian, E., Samiei, N., Mahgoli, M. H., & Ghane, H. K. (2021). Accuracy of digital impression taking using intraoral scanner versus the conventional technique. Frontiers in Dentistry, 18. https://doi.org/10.18502/fid.v18i6.5649
Zarone, F., Ruggiero, G., Ferrari, M., Mangano, F., Joda, T., & Sorrentino, R. (2020). Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis. Journal of Prosthetic Dentistry, 124(6). https://doi.org/10.1016/j.prosdent.2020.07.018
License
Copyright (c) 2025 Rahmi Ayu Budi Amalia, Indra Bramanti, Sri Budi Barunawati, Suryono, Ismianti

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with Jurnal Penelitian Pendidikan IPA, agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution 4.0 International License (CC-BY License). This license allows authors to use all articles, data sets, graphics, and appendices in data mining applications, search engines, web sites, blogs, and other platforms by providing an appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in Jurnal Penelitian Pendidikan IPA.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).






