Abstract

This study aims to characterize the phosphate buffer and urease enzymes through UV-Vis and SEM-EDS absorbance spectra using tungsten as an indicator electrode. The method used is a potentiometric biosensor with urease enzyme immobilization technique for urea analyte. A small detection range of 10-5-10-4M has been studied with PVA-enzyme coated indicator electrodes coated with PVC-KTpClPB. On this basis, the researchers increased the detection range by analyzing glutaraldehyde (GA) mixed with PVA-enzyme and o-NPOE mixed with PVC-KTpClPB. The best results of GA mixed PVA-enzyme at GA2.9% UV-Visible analysis. The best results were PVA-enzyme coated indicator electrodes coated with GA coated again with PVC-KTpClPB-o-NPOE SEM-EDS analysis on PVA-enzyme samples 3x coated with GA 1x and PVC-KTpClPB-o-NPOE 1x with o-NPOE variation of 61% and 66%.

Keywords:

UV-Visible and SEM-EDS GA and o-NPOE tungsten indicator electrode Biosensor potentiometry Immobilization

References

Badakhshan, S., Ahmadzadeh, S., Mohseni-Bandpei, A., Aghasi, M., & Basiri, A. (2019). Potentiometric sensor for iron (III) quantitative determination: experimental and computational approaches. BMC Chemistry, 13(1), 131. https://doi.org/10.1186/s13065-019-0648-x

Basile, A., Bhatt, A. I., & O’Mullane, A. P. (2016). Stabilizing lithium metal using ionic liquids for long-lived batteries. Nature Communications, 7(1), ncomms11794. https://doi.org/10.1038/ncomms11794.

Bhushan, B., Pal, A., & Jain, V. (2015). Improved Enzyme Catalytic Characteristics upon Glutaraldehyde Cross-Linking of Alginate Entrapped Xylanase Isolated from Aspergillus flavus MTCC 9390. Enzyme Research, 2015, 210784. https://doi.org/10.1155/2015/210784.

Elbehery, N. H. A., Amr, A. E.-G. E., Kamel, A. H., Elsayed, E. A., & Hassan, S. S. M. (2019). Novel Potentiometric 2,6-Dichlorophenolindo-phenolate (DCPIP) Membrane-Based Sensors: Assessment of Their Input in the Determination of Total Phenolics and Ascorbic Acid in Beverages. In Sensors. 19(9). https://doi.org/10.3390/s19092058.

Escudero, A., de los Ríos, A. P., Godínez, C., Tomás, F., & Hernández-Fernández, F. J. (2020). Immobilization in Ionogel: A New Way to Improve the Activity and Stability of Candida antarctica Lipase B. In Molecules. 25(14). https://doi.org/10.3390/molecules25143233

Hakim S.A., Sembiring, T, Tarigan, K., Sebayang, K., Situmorang, M., and Noer, N. M, (2019) Characterization of Membrane PVA-Enzyme Coated PVC-KTpClPB as Urea Sensor with Potentiometric Method, Rasayan Journal of Chemistry, 12, 780–786. https://doi.org/10.31788/RJC.2019.1225143.

Hakim S.A., Situmorang, M., Sebayang, K., Sembiring, T., Tarigan, K., Mihardi1, S., Noor, N.M., and Elnovreny, J., (2021). Characterization Of Urea Analyte Solution and Electrolyte Solution Using Non-Immobilized Electrode Indicators and Pva-Enzyme Coated Pvc-Ktpclpb Immobilization, Rasayan Journal of Chemistry, 14, 2021. https://doi.org/10.31788/RJC.2021.1426103.

Hakim S.A., Tarigan, K., Situmorang, M., & Sembiring, T. (2018). Synthesis of Urea Sensors using Potentiometric Methods with Modification of Electrode Membranes Indicators of ISE from PVA-Enzymes Coating PVC-KTpClPB. Journal of Physics: Conference Series, 1120, 12024. https://doi.org/10.1088/1742-6596/1120/1/012024.

Huang, S., Luo, F., and Lai, X., (2014), Novel Potentiometric Sensors of Ion Imprinted Polymers for Specific Binding of Yttrium(III), Asian Journal of Chemistry; Vol. 26, No. 20 : 6787-6790. https://doi.org/10.14233/ajchem.2014.16795

Ismaiel, A. A., Aroua, M. K., & Yusoff, R. (2014). Cadmium (II)-selective electrode based on palm shell activated carbon modified with task-specific ionic liquid: kinetics and analytical applications. International Journal of Environmental Science and Technology, 11(4), 1115–1126. https://doi.org/10.1007/s13762-013-0296-y.

Kaur, H., Chhibber, M., & Mittal, S. K. (2017). Acyclic Arylamine-Based Ionophores as Potentiometric Sensors for Zn2+ and Ni2+ Ions. In C (Vol. 3, Issue 4). https://doi.org/10.3390/c3040034.

Kim, E., Liu, Z., Liu, Y., Bentley, W. E., & Payne, G. F. (2017). Catechol-Based Hydrogel for Chemical Information Processing. In Biomimetics 2(3). https://doi.org/10.3390/biomimetics2030011.

Lenar, N., Paczosa-Bator, B., & Piech, R. (2020). Optimization of Ruthenium Dioxide Solid Contact in Ion-Selective Electrodes. In Membranes. 10(8). https://doi.org/10.3390/membranes10080182

Lin, J., Pan, D., Sun, Y., Ou, C., Wang, Y., & Cao, J. (2019). The modification of gelatin films: Based on various cross-linking mechanism of glutaraldehyde at acidic and alkaline conditions. Food Science & Nutrition, 7(12), 4140–4146. https://doi.org/https://doi.org/10.1002/fsn3.1282

Mir, M., Lugo, R., Tahirbegi, I. B., & Samitier, J. (2014). Miniaturizable Ion-Selective Arrays Based on Highly Stable Polymer Membranes for Biomedical Applications. In Sensors 14(7). https://doi.org/10.3390/s140711844.

Pogorilyi, R. P., Pylypchuk, I., Melnyk, I. V., Zub, Y. L., Seisenbaeva, G. A., & Kessler, V. G. (2017). Sol-Gel Derived Adsorbents with Enzymatic and Complexonate Functions for Complex Water Remediation. Nanomaterials (Basel, Switzerland), 7(10), 298. https://doi.org/10.3390/nano7100298

Rahman, M. A., Kumar, P., Park, D.-S., & Shim, Y.-B. (2008). Electrochemical Sensors Based on Organic Conjugated Polymers. Sensors, 8(1), 118–141. https://doi.org/10.3390/s8010118.

Ulianas, A., Heng, L. Y., & Ahmad, M. (2011). A biosensor for urea from succinimide-modified acrylic microspheres based on reflectance transduction. Sensors (Basel, Switzerland), 11(9), 8323–8338. https://doi.org/10.3390/s110908323.

Author Biography

Abd Hakim S, Universitas Negeri Medan

Author Origin : Indonesia

Downloads

Download data is not yet available.

How to Cite

S, A. H. (2021). Characterization of PVA-Enzyme Coated Indicator Electrodes GA coated again with PVC-KTpClPB-o-NPOE UV-Vis analysis, variable signal analysis, sensor sensitivity and SEM-EDS. Jurnal Penelitian Pendidikan IPA, 7(SpecialIssue), 370–376. https://doi.org/10.29303/jppipa.v7iSpecialIssue.1248