Automatication of Thickness Slice Measurement Using Non-Rotation Method on Three Ladder Objects from Computed Tomography
DOI:
10.29303/jppipa.v11i3.9978Published:
2025-03-25Issue:
Vol. 11 No. 3 (2025): MarchKeywords:
CT-scan, Slice thickness, Non-rotational method, AAPM CT Performance PhantomResearch Articles
Downloads
How to Cite
Downloads
Metrics
Abstract
To perform slice thickness calculation automatically using the non-rotational method on the three ladder objects in the AAPM CT Performance Phantom image. Phantom was scanned with a GE Healthcare 128-slice CT scan scanner using slice thicknesses of 0.625 mm, 5.0 mm, and 10.0 mm. The software was developed with a non- rotational method to be able to measure the FWHM value and the mean on the three rungs of the object. In addition, the FWHM of the non-rotational method was compared with the rotational method The FWHM value from automatic measurement for slice thickness is 0.625 mm in three slice variations with non-rotational method 1.68 mm and rotation method 1.61 mm while for slice thickness 5.0 mm on non-rotation method is 6.51 mm, rotation method is 6.68 mm. , and for a slice thickness of 10.0 mm for the non-rotational method 9.58 mm and the rotational method 9.75 mm. The results of the non-rotational method were slightly lower (i.e. 1,74%) than the results of the rotational method for each nominal slice thickness, except for the smallest slicethickness The automatic slice thickness measurement algorithm on AAPM CT Performance Phantom has been improved using a non-rotational method. The improved algorithm can overcome the widening problem that occurred in the previous method due to object rotation.
References
Anggraeni, L. (2023). Analysis Procedure Of CT Scan Examination Of Paranasal Sinuses Using Contrast Media With Clinical Tumor Cavum Nasi. Journal Of Health Terraces, 6(1), 8-15. https://doi.org/10.38215/jtkes.v6i1.107
Annette, A. (2025). Prosedur Penatalaksanaan Computed Tomography ( CT Scan ) Os . Cruris Dengan Klinis Suspect Tumor Di Unit Radiologi. 5(November 2024), 2637-2646.
April, D., Milvita, D., Prasetio, H., & Yuliati, H. (2013). Effect Of Phantom Diameter And Slice Thickness On Ctdi Value On Ct-Scan. Unand Journal Of Physics, 2(2), 81-87.
Bisra, M., Hulmansyah, D., & Artata, A. (2024). RECONSTRUCTION. 5, 10508–10516.
Destri Bestari Palimbong, Anak Agung Aris Diartama, & I Kadek Sukadana. (2023). Analisis Multi Slice Computed Tomography (MSCT) Nasofaring Dengan Klinis Karsinoma Nasofaring Di Instalasi Radiodiagnostik RSUP Dr. Hasan Sadikin Bandung. Journal Of Health Sciences, 3(3), 17-28. https://doi.org/10.55606/jpikes.v3i3.2672
Dewilza, N., Artitin, C., Yudha, S., Fahmi, D. M., Study, P., Radiology, D., ... Baiturrahmah, U. (2023). Menggunakan Protokol Fast Stroke. Tambusai Journal Of Health, 4(4), 6547-6554.
Fitriania, H., Kurnia, A., Ramadani, D., & Fatimah. (2022). Analisis CT Scan Cardia Klinis Chest Pain di Rumah Sakit Bhayangkara Makassar. Indonesian Multidisciplinary Scientific Journal, 1(9), 1278-1285.
Fitriyasari, M. (2023). Deteksi Covid-19 Pada Citra Ct-Scan Menggunakan K-Nearest Neighbor. JIPI (Scientific Journal of Informatics Research and learning), 8(1), 331-337. https://doi.org/10.29100/jipi.v8i1.3996
Glorianismus, F. Y., Empress, N., Watiningsih, S. D., Ayu, T., & Trevesia, V. (2023). Optimalisasi Citra Ct Scan Kepala Pada Kasus Stroke Non Hemoregik Dengan Variasi Slice Thickness Dan Interval Reconstruction Di Rs X Denpasar. Indonesian Multidisciplinary Scientific Journal, 1(9), 1278-1285.
Hariani, I. A. S., Prasetya, I. M. L., & Mahendrayana, I. M. A. (2024). Thorax Ct Scan Examination Procedure As A Guiding FNAB Examination In Cases Of Lung Tumors In The General Hospital Of West Nusa Tenggara Province (Ntb). Journal of medical and Health Sciences, 10(12), 3621-3633. https://doi.org/10.33024/jikk.v10i12.12283
Herlinda, S., Fitriyani, D., & Marzuki, M. (2019). Analisis Pengaruh Kuat Arus dan Tegangan Terhadap Kualitas Citra Computed Tomography (CT) Scan Siemens Perspective di RSUP Dr. M. Djamil Padang. Positron, 9(1), 39. https://doi.org/10.26418/positron.v9i1.31138
Wisdom, I., Beautiful Full Moon, S., Prayugo Hariyanto, A., & Nur Afifah Zen, and. (2023). Optimization of the dose and image quality of the CT-Scan plane on the eye using Shielding for CT-Scan imaging of the head. Journal of theoretical and Applied Physics, 11(01), 73-80.
Irfan Irfan, & Rahmat Widodo. (2024). Conduct abdominal CT Scan examination with contrast with clinical CA Recti. Diagnosis: Journal of Health Sciences and nursing, 2(1), 113-123. https://doi.org/10.59581/diagnosa-widyakarya.v2i1.2711
Journal, C., Health, I., Obstetrics, K., Engineering, A., Road, A., Batanghari, T., ... Klod, D. P. (2024). Analysis of Safire's results on CT imaging of Irfan's head is sourced from x-rays and can display anatomical images in an emergency crossectional manner where patients experience head injuries , stroke symptoms and trauma. 2(3).
Kartika Sari, N. L. Happy, D. T., Hartoyo, P., & Muliyati, D. (2021). The Effects Of High Dose and Low Dose Protocols In Thorax’s CT Scan Image Quality. Indonesian Journal of Applied Physics, 11(2), 189. https://doi.org/10.13057/ijap.v11i2.48365
Karulina Imanda Muhamad, W., Ngurah Sutapa, G., Gde Antha Kasmawan, I., Irhas, R., Physical Studies, P., Mathematics and Natural Sciences, F., ... Badung, K. (2022). Analisis Pengaruh Field of View (FOV) Terhadap Kualitas Citra Pesawat CT Scan di RSU Bali Jimbaran. December 2022, 6(2), 383-389. Diambil dari http://e-journal.hamzanwadi.ac.id/index.php/kpj/index
Kastiwi, R. E. (2022). Optimization of Ct-Spn Anatomical Image of Coronal Section With Slice Thickness Reconstruction Variations and Increment Reconstruction in Rhinosinusitis Cases Chronic at Rs Balimed. Journal of Social Research, 1(12), 587–598. https://doi.org/10.55324/josr.v1i12.372
Kusumawardani, A. W., Theresia, E. M., & Tricks, W. N. (2010). Pre-Pregnancy Obesity And The Incidence Of Preeclampsia In Hypertensive Mothers. Photon: Journal of Science and Health, 5(1), 91-96. https://doi.org/10.37859/jp.v5i1.400
The List, I. L., Nismayanti, A., Maskur, M., Kasman, K., Ulum, M. S., & Rahman, A. R. (2021). Noise Level analysis of CT-Scan image results on Phantom head with variation of Tube tension and slice thickness. Gravity, 20(1), 5-9. https://doi.org/10.22487/gravitasi.v20i1.15517
Madja, M. N., Ali, R. H., & Loho, E. (2013). Gambaran hasil ct scan kepala pada penderita nyeri kepala di bagian radiologi fk unsrat/smf radiologi blu rsup prof. Dr. R. D. Kandou manado period 1 january-31 december 2011. Journal of e-Biomedicine, 1(1), 512-517. https://doi.org/10.35790/ebm.1.1.2013.4592
Maghfirah, A., Rahim, A., & Fadhlin, A. (2024). Linearity Test of CT Number and Spatial Resolution Using ACR 464 Phantom for Image Quality Assessment on a 16-Slice CT Scanner. 06(02), 79–83. https://doi.org/10.32734/jotp.v6i2.12410.This
Noveranty, A., Purwaningsih, S., & Fendriani, Y. (2024). 35155-Article Text-108444-1-10-20240805. 9(3), 53–59.
Puspaningrum, S., Putu, N., Jeniyanthi, R., & Darmita, I. M. P. (2023). Analysis of CT Number value in Thorax CT Scan examination in pleural effusion cases at Bhayangkara Hospital Makassar. Nautical: A Multidisciplinary Scientific Journal, 1(10), 1212-1216.
Puspitaningtyas, D. A. (2023). Peranan Pemeriksaan Ct Scan Kepala Dalam Penegakkan Diagnosa Stroke Ischemic : Studi Literature.
Rahmat, R., Rahmah Akademi Teknik Radiodianostik dan radiotherapy Bali, R., Kadek Yuda Astina Academy of Radiodianostic and radiotherapy techniques Bali, I., & Bagus Gede Dharmawan Academy of Radiodianostic Engineering and radiotherapy Bali, I. I. (2023). Analysis of CT Scan examination of the neck with contrast in the case of thyroid tumors in the radiology installation of the NTB Provincial Hospital. Journal of Educational Innovation and Public Health, 1(4), 252–264. Diambil dari https://doi.org/10.55606/innovation.v1i4.1910
Rahmawati, D., Great, A., Diartama, A., Widodo, R., Engineering, A., And, R., & Bali, R. (2024). Technique of abdominal CT Scan examination in case of Intra abdominal Tumor in X Hospital Radiology installation. Journal of Health and Nutrition Sciences(JIG), 2(1), 22-40. Diambil dari https://doi.org/10.55606/jikg.v2i1.2093
Ricky Richard Ivanson Tude, Aris Diartama, & Made Purwa Darmita. (2024). Uji Kesesuaian CT Number Pada Pesawat CT Scan Multislice Di Rumah Sakit Sunset Vet Kuta. Antigen: Journal of Public Health and Nutritional Sciences, 2(1), 106-113. https://doi.org/10.57213/antigen.v2i1.205
Rohadi, R., Priyanto, B., Januarman, J., Hadi, S., Tenti, D., Faulani, W., & Zulkarnaen, D. A. (2023). Workshop Membaca Ct Scan Kepala Bagi Dokter Umum Se-Ntb. Pepadu Journal, 4(4), 568-573. https://doi.org/10.29303/pepadu.v4i4.3749
Safitri, R., Evi, Y., & Combs, P. (2011). Analysis quality control (QC) on CT scan in RSUZA Banda Aceh an effort to get the best quality in image. 1(2), 139–143.
Sambawitasia, I. P. Y. (2022). CT stonography examination technique in nephrolithiasis cases at the radiology installation of Buleleng District Hospital. Nautical : Indonesian Multidisciplinary Scientific Journal, 1(9), 868-873. Diambil dari https://jurnal.arkainstitute.co.id/index.php/nautical/article/view/488
The Princess, L. D., Santoso, B., Oktavianto, A. N., & Anita, F. (2019). Analisis Dosis Serap CT Scan Thorax Dengan Computed Tomography Dose Index Dan Thermoluminescence Dosimeter. Scientific Journal Giga, 20(1), 10. https://doi.org/10.47313/jig.v20i1.546
The Faithful, E., Radiodiagnostik dan Radioterapi Bali, A., & Radiology Hospital Primaya Tangerang, D. (2024). Management of cardiac CT-Scan examination with modified Management in case of high Heart Rate at Primaya Tangerang Hospital. Scientific journal of Health Sciences and Medicine, 2(1), 66-71. Diambil dari https://doi.org/10.55606/termometer.v2i1.2799
Sofiyatun, S., Anam, C., Zahro, U. M., Rukmana, D. A., & Dougherty, G. (2021). An Automated Measurement of Image Slice Thickness of Computed Tomography. Atomic Indonesia, 47(2), 121-128. https://doi.org/10.17146/aij.2021.1111
Teroci, J., Academy, M., Radiodiagnostik, T., Washington, D.C., Kadek, I., Astina, Y., ... Diartama, I. A. A. A. (2024). Effective dose analysis on CT-SCAN of contrast head in Radiology installation of Surya Husadha Hospital Denpasar. Journal Of Traditional Health, 2(1), 208-213. Diambil dari https://doi.org/10.47861/usd.v2i1.675
Primary, H. S., Azizah, A. N. The Rain, A. M., Susanto, F., & Oviyanti, P. N. (2023). Studi Kualitatif: Analisis Informasi Anatomi Pada Variasi Slice Thickness Msct Scan Orbita Dengan Media Kontras Potongan Axial Mpr. Journal Of Health, 14(1), 36-41. https://doi.org/10.38165/jk.v14i1.342
Virgin, Y. A., Astina, K. Y., & Pratista, S. (2023). Estimation of radiation dose on CT-Scan of non-contrast adult head based on CTDI and DLP value in Radiology installation of Tk II Pelamonia hospital. Nautical: A Multidisciplinary Scientific Journal, 1(10), 1147-1152. Diambil dari https://jurnal.arkainstitute.co.id/index.php/nautical/article/view/536/458
Wahyuni, S., & Amalia, L. (2022). Perkembangan Dan Prinsip Kerja Computed Tomography (CT Scan). GALENICAL : Journal of Medicine and Student Health Malikussaleh, 1(2), 88. https://doi.org/10.29103/jkkmm.v1i2.8097
Author Biographies
Dewi Angraini Insiano, Madako Tolitoli University
Hasia Marto, Madako Tolitoli University
License
Copyright (c) 2025 Dewi Angraini Insiano, Hasia Marto

This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with Jurnal Penelitian Pendidikan IPA, agree to the following terms:
- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution 4.0 International License (CC-BY License). This license allows authors to use all articles, data sets, graphics, and appendices in data mining applications, search engines, web sites, blogs, and other platforms by providing an appropriate reference. The journal allows the author(s) to hold the copyright without restrictions and will retain publishing rights without restrictions.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in Jurnal Penelitian Pendidikan IPA.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).